Combined type transformer(American type)
ZGS COMBINED TYPE TRANSFORMER SUBSTATION
ZGS11 combined type transformer substation is more compact than the YBM type substation. It follows American design and uses compact low voltage switches to reduce volume, thus to lower the cost.
Benefits
- Compact and low cost
- Low loss and strong over-load ability
- Low noise, energy conservation and environmental protection
- High mechanical strength, good performance
Installation conditions
- Ambient air temperature: -25°C ~ +40°C;
- Relative humidity ≤ 95% (+25℃)
- Altitude ≤1000m;
- Wind speed ≤ 35m/s;
- Horizontal acceleration ≤ 0.4m/s2, Vertical acceleration≤ 0.2m/s2;
- Installation places should without conductive dust, corrosive nor explosion gas. No violent vibration, vertical gradient<3º.
If the switchgear will be used in conditions that exceed the normal environmental conditions, please consult with us.
Application
ZGSCombined type transformer substation is reliable power supply.It is very compact and low cost, easy for installation, operation and maintains. It’s widely used in industrial park, high buildings, residential district, labor, wharf, airport, hotel, business center, etc.
Standard
GB1094.1, .2-2013
GB/T6451-2008
GB1094.3.5-2003
DL/T 537-93
ZBK4001-89
Model code
The low voltage cabinet is specially equipped with intelligent under voltage controller, which has the function of identifying the abnormal voltage of the low voltage busbar of the substation, and can also avoid the tripping function of the low voltage switch caused by the trip of the 10kV high voltage line or during power outage maintenance.
Technical parameters
Model | Rated Capacity | Connection | Rated Voltage | No-load cost | On-load cost (145℃) |
No-load current | short circuit impedance | Dimension (L*W*H) |
||
HV | Tapping range | LV | ||||||||
(kVA) | kV | kV | (W) | (W) | (%) | (%) | (mm) | |||
ZGS11-Z(H)-100/10 | 100 | Yyn0 or Dyn11 |
6 6.3 10 10.5 11 |
±2*2.5% ±5% |
0.4 | 200 | 1500 | 0.8 | 4 | 2200*1500*1800 |
ZGS11-Z(H)-125/10 | 125 | 240 | 1800 | 0.8 | 2200*1500*1800 | |||||
ZGS11-Z(H)-160/10 | 160 | 280 | 2200 | 0.7 | 2200*1500*1800 | |||||
ZGS11-Z(H)-200/10 | 200 | 330 | 2600 | 0.7 | 2200*1500*1800 | |||||
ZGS11-Z(H)-250/10 | 250 | 400 | 3050 | 0.6 | 2200*1500*1800 | |||||
ZGS11-Z(H)-315/10 | 315 | 480 | 3650 | 0.6 | 2500*1600*1800 | |||||
ZGS11-Z(H)-400/10 | 400 | 560 | 4300 | 0.5 | 2500*1600*1800 | |||||
ZGS11-Z(H)-500/10 | 500 | 680 | 5100 | 0.5 | 2500*1600*1800 | |||||
ZGS11-Z(H)-630/10 | 630 | 810 | 6200 | 0.5 | 4.5 | 2600*1700*1800 | ||||
ZGS11-Z(H)-800/10 | 800 | 980 | 7500 | 0.4 | 2600*1700*1800 | |||||
ZGS11-Z(H)-1000/10 | 1000 | 1150 | 10300 | 0.4 | 2600*1700*1800 | |||||
ZGS11-Z(H)-1250/10 | 1250 | 1360 | 12000 | 0.4 | 2700*1800*2000 | |||||
ZGS11-Z(H)-1600/10 | 1600 | 1600 | 14500 | 0.3 | 2700*1800*2000 |
Note: All the dimension and weight is for reference only.
The substation is divided into three main units – high voltage unit, transformer unit, low voltage unit. Each unit contains temperature control system, lighting system and display system. The equipment and the box both achieve IP33 protection
INTERESTED IN US, FOR MORE PRODUCT INFORMATION, PLEASE CONTACT US!
INTERESTED IN US, FOR MORE PRODUCT INFORMATION, PLEASE CONTACT US!
Contact infomation:
Tel / Skype/Whatsapp/wechat:
E-mail:
fuchenelectrical@163.com
Address:
No.30 Mingsha north load,South China Hardware Industry Base,Danzao town Nanhai district,Foshan,GuangDong,China 528216
Message to us